speclib maintains a tiered quality system to ensure data integrity while welcoming community contributions.

Quality Tiers

Tier Source Entry Method Review
VERIFIED USGS splib07, ECOSTRESS, ASTER/JPL Automated ingestion from authoritative sources Peer-reviewed upstream libraries
CURATED Maintainer field data (KY chapter) Direct ingestion by project maintainers Maintainer-verified instruments and calibration
COMMUNITY Researcher contributions GitHub PR with validation CI format checks + maintainer credential review

Data Requirements

All spectral data in speclib must meet these minimum standards regardless of tier:

Calibration

  • Calibrated reflectance only — all spectra must be calibrated against a known reference standard
  • Raw DN values, uncalibrated measurements, and transmission spectra are not accepted
  • Contributors must document their calibration method (e.g., Spectralon white reference panel, vicarious calibration, atmospheric correction)
  • Reflectance values must be on a 0.0-1.0 scale (fractional, not percentage)

Wavelength

  • Wavelengths must be in micrometers (um)
  • Wavelength arrays must be sorted in ascending order
  • Non-uniform spacing is acceptable (store as measured, do not resample)

Metadata

Every spectrum must carry:

  • Material name and category classification
  • Source library identifier and original record ID
  • Measurement type (laboratory, field, airborne, spaceborne)
  • License for data use
  • Instrument used for measurement

Spectral Integrity

  • Spectral gaps are stored as NaN, never interpolated
  • Out-of-range reflectance values (outside 0.0-1.0) are flagged with a warning, never silently clipped
  • Delete values from upstream sources (e.g., USGS -1.23e+34) are converted to NaN

Contribution Review Process

Community contributions go through a two-stage review:

Stage 1: Automated Validation (CI)

The CI pipeline automatically checks:

  • contribution.yaml has all required fields
  • calibrated: true is set
  • calibration_method is non-empty
  • Contributor affiliation and email are provided
  • CSV data parses correctly
  • Wavelengths are sorted ascending
  • Reflectance values are in [0.0, 1.0]
  • Wavelength and reflectance arrays are the same length

Stage 2: Maintainer Review

A project maintainer manually verifies:

  • Contributor credentials — institutional affiliation is legitimate
  • Instrument and calibration — measurement setup is appropriate for the claimed data
  • Data quality — spectra look physically reasonable (no obvious artifacts, saturation, or noise issues)
  • Metadata completeness — description, locality, and citation are adequate
  • License compatibility — data license is compatible with the project (GPL-3.0 for code, CC-BY-4.0 recommended for data)

Promotion

After merging, community contributions remain in the COMMUNITY tier. A maintainer can promote contributions to CURATED status after additional verification (e.g., comparing against known reference spectra, confirming measurement conditions).

Instruments

speclib accepts data from any calibrated spectrometer or imaging spectrometer. Common instruments include:

Instrument Type Typical Range
ASD FieldSpec (¾) Portable field spectrometer 0.35-2.5 um
CID CI-710 Leaf spectrometer 0.40-0.95 um
Spectral Evolution PSR+ Portable spectrometer 0.35-2.5 um
Ocean Optics USB series Compact spectrometer 0.20-1.1 um
AVIRIS / AVIRIS-NG Airborne imaging spectrometer 0.38-2.5 um
HyMap Airborne imaging spectrometer 0.45-2.5 um
EMIT Spaceborne imaging spectrometer 0.38-2.5 um

Drone-mounted spectrometers and hyperspectral cameras are welcome as long as the data has been radiometrically calibrated and atmospherically corrected.